Home / Solutions / Hardware / Power and Cooling /
 
 
Quadnet IT
 

Power and Cooling

For all your IT solutions:

Telephone

020 8988 5959

Fax

020 8988 7719

Email

sales@quadnet.co.uk

 

Introducing the APC-MGE Efficient Enterprise

What is it, why you need it, and how it becomes a cost effective solution

Efficiency has become a significant factor in purchasing decisions for more and more customers. Through Quadnet, APC can offer customers a predictable, efficient high-density environment that positions them for growth in the future.

Introducing the revolutionary enterprise architecture that offers tomorrow's solutions to today's problem: the Efficient Enterprise. This solution employs the "4 C's" to optimise data efficiency- four principles to ensure a more predictable, waste free date centre environment that saves energy, boosts availability, and allow for future growth. These principles are:

  • Containing the heat
  • Closely coupling the cooling to the heat source
  • Right sizing components
  • Managing capacity

Hot Air Containment

A predictable solution for an unpredictable environment

Delivering cold air to the data centre is not the problem. Getting rid of the hot air is. When the hot air exhaust generated by high-density applications mixes with the cooler ambient air, the airflow around the data centre becomes unpredictable and localised "hot spots" crop up.

The legacy-system approaches of adding cooling capacity and lowering the temperature set point do not solve the problem, which is one of air distribution. The Hot Air Containment Systemensures proper airflow by completely separating supply and return air paths. By sealing off the hot aisle, the hot exhaust is captured at its source, before it ever has a chance to mix with the cooler ambient air. Airflow paths become well defined and predictable.

Close-Coupled Cooling

Pinpoint control

The innovative APC-MGE InRow architecture,with its close-coupled cooling design, reduces the distance between the heat source and the heat removal system-bringing the cooling right to where the heat is generated. This permits more control over airflow and prevents the hot exhaust air from mixing with the ambient air.

Cooling never reaches the problem hot spots deeper in the aisles with the "circle the wagons" approach of legacy perimeter cooling systems.

Right-sized components

Pay as you grow

Growth is good, but it's unpredictable. Due to this, companies oversize their components. And when it comes to power and cooling, this overkill is a high waste of resources. APC-MGE has come up with  a "pay as you grow" system of scalable modular architecture that allows for powering and cooling only what is needed when it's needed. Right-architecture lets you offer your customer the flexibility to expand without the wasteful cost of idle equipment.

Capacity management

A crystal ball for IT needs

The comprehensive suite of APC-MGE enterprise management software applications provides unparalleled insight into the data centre over its entire life cycle. One powerful platform allows IT managers to optimise resources, plan future needs accurately, and incorporate changes smoothly.